ANALISIS KEANDALAN DAN SUSUT DAYA SISTEM DISTRIBUSI 20 KV ULP DAYA AKIBAT PENGALIHAN BEBAN PENYULANG BADDOKA KE PENYULANG UJUNG PANDANG
Edisi 2 Tahun 2023
PDF (English)

Kata Kunci

Load Shifting
SAIDI
SAIFI
Power Loasses.

Abstrak

Electricity is vital, depending on generator, transmission, and distribution systems. Transformer damage at substations (GI) disrupts supply, necessitating load transfer from Baddoka to Ujung Pandang. This study assesses feeder performance pre and post-transfer, evaluating reliability (SAIDI and SAIFI) and feeder losses for the receiving feeders. In this research, feeder reliability is evaluated using SAIDI and SAIFI indices. The method involves calculating pre-transfer indices based on feeder outage history and post-transfer indices using the RIA method. Furthermore, calculations for feeder loss are carried out. before and after the transfer using conventional methods for medium-voltage network channels and distribution substations. The aim is to measure energy supply reliability and efficiency in electricity distribution. In the pre-transfer analysis, Ujung Pandang feeder had a SAIDI of 3.6956 hours/customer/year and a SAIFI of 8.7952 times/customer/year, while Baddoka feeder had a SAIDI of 3.0073 hours/customer/year and a SAIFI of 8.5487 times/customer/year. Ujung Pandang had a 1.85% power loss, and Baddoka had a 1.78% loss. After transferring the full load from Baddoka to Ujung Pandang (using RIA), SAIDI increased to 31.1399 hours/customer/year, SAIFI decreased to 6.6933 times/customer/year, and power loss slightly rose to 1.98%. Before the transfer, Baddoka met the 1986 SPLN No. 68-2 standard with a SAIDI of 21.09 hours/customer/year and SAIFI of 3.2 times/customer/year. Ujung Pandang's SAIDI complied, but power loss met the 1987 SPLN No. 72 standard. Post-transfer, Ujung Pandang needed maneuvers to Marannu and Sudiang under GI Daya Baru and Baddoka under GI Kima to meet reliability and power loss standards, resulting in SAIDI 12.1281 hours/customer/year, SAIFI 3.0756 times/customer/year, and power loss 2.02%
PDF (English)

Referensi

Ramesh, L., Chowdhury, S., Chowdhury, S., Natarajan, A., & Gaunt, C. (2009). Minimization of power loss in distribution networks by different techniques. International Journal of Electrical and Computer Engineering, 3(4), 661-667.

Kang, M.-S., Chen, C.-S., Lin, C.-H., Huang, C.-W., & Kao, M.-F. (2006). A systematic loss analysis of Taipower distribution system. IEEE Transactions on Power Systems, 21(3), 1062-1068.

Fadhliyansyah, M. (2018). Analisis Perhitungan Rugi-Rugi Transformator Akibat Harmonisa (Studi Kasus Gardu Distribusi Smti Pontianak). Jurnal Teknik Elektro Universitas Tanjungpura, 2(1).

Funan, F., & Sutama, W. (2020). Evaluasi Keandalan Sistem Distribusi Tenaga Listrik Berdasarkan Indeks Keandalan SAIDI dan SAIFI pada PT PLN (PERSERO) Rayon Kefamenanu. Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi, 3(2), 32-36.

Gede, D. A. (2014). Analisis Drop Tegangan dan Susut Daya pada Jaringan Listrik Penyulang Renon Menggunakan Metode Artificial Neural Network. Jurnal Teknik Elektro Universitas Udayana.

Handoyo, A., Sukmadi, T., & Warsito, A. (2011). Analisa Perhitungan Susut Teknik pada PT. PLN (Persero) UPJ Semarang Tengah Jurusan Teknik Elektro Fakultas Teknik].

Latupeirissa, H. L., Muskita, H. M., & Tahalele, T. J. (2020). Analisa Susut Daya Pada Sistem Distribusi Jaringan Tegangan Menengah. JURNAL SIMETRIK, 10(1), 313-321.

Nurhaq, M. A. (2022). STRATEGI OPERASI SISTEM PADA PEMELIHARAAN PENYULANG CAMBA PLN UP3 MAKASSAR UTARA= OPERATION SYSTEM STRATEGY ON MAINTENANCE OF CAMBA FEEDER PLN UP3 MAKASSAR UTARA Universitas Hasanuddin].

Arigandi, G. P. B., Hartati, R. S., & Weking, A. I. (2015). Analisa Keandalan Sistem Distribusi Penyulang Kampus Dengan Menggunakan Penggabungan Metode Section Tecknique Dan Ria. Maj. Ilm. Teknol. Elektro, 14(2), 1.

Zuhal. 1991. Dasar Tenaga Listrik. Bandung: ITB.

Hontong, N. J., Tuegeh, M., & Patras, L. S. (2015). Analisa rugi–rugi daya pada jaringan distribusi di PT. PLN Palu. Jurnal Teknik Elektro dan Komputer, 4(1), 64-71.