Monitoring the Condition of the 20 kV Switching Substation in the Tual Rayon Saumlaki Area

Andareas Pangkung, Sonong Sonong, Makmur Saini, Muhammad Ruswandi Djalal, M Fachmi Jamal

Abstract


A 20 kV cubicle is a set of electrical equipment installed in a distribution substation as a distributor, circuit breaker, connector, controller, and protection system for the 20 kV voltage power distribution. The frequent issue in these cubicles is corona discharge on electrical equipment, which is a phenomenon occurring when the air around conductors or conductive materials becomes ionized, resulting in the release of charges that can lead to insulation failure in the equipment. The consequences are severe as it can damage the equipment inside the cubicle and cause power losses. This research analyzes the influence of humidity, temperature, sound, and light conditions inside the cubicle to identify the symptoms of corona discharge in the 20 kV cubicle and its accessories. The goal is to create a tool that can address and anticipate the issues related to corona discharge caused by the effects of humidity, temperature, sound, and light.

Full Text:

PDF

References


J. C. do Prado, W. Qiao, L. Qu, and J. R. Agüero, "The next-generation retail electricity market in the context of distributed energy resources: Vision and integrating framework," Energies, vol. 12, no. 3, p. 491, 2019.

D. Jovcic, High voltage direct current transmission: converters, systems and DC grids. John Wiley & Sons, 2019.

N. M. Zainuddin et al., "Review of thermal stress and condition monitoring technologies for overhead transmission lines: Issues and challenges," IEEE Access, vol. 8, pp. 120053-120081, 2020.

A. Irsal, B. Denov, and R. Zoro, "Lightning Protection System on Substation Extra High Voltage 500 kV Sumatera, Indonesia," in 2019 International Conference on Electrical Engineering and Informatics (ICEEI), 2019: IEEE, pp. 672-677.

J. Hartono, M. Ridwan, M. M. Mafruddin, H. Habibi, and E. Anugrahany, "500 kV quadruple circuit compact transmission line redesign study to reduce the impact of lightning strikes," in 2021 3rd International Conference on High Voltage Engineering and Power Systems (ICHVEPS), 2021: IEEE, pp. 263-267.

I. O. Zaitsev and V. V. Kuchanskyy, "Corona discharge problem in extra high voltage transmission line," Systems, Decision and Control in Energy II, pp. 3-30, 2021.

V. Kuchanskyy and I. O. Zaitsev, "Corona discharge power losses measurement systems in extra high voltage transmissions lines," in 2020 IEEE 7th International Conference on Energy Smart Systems (ESS), 2020: IEEE, pp. 48-53.

M. De La Hoz, A. Etxegarai, A. M. Larrea, A. J. Mazon, and M. A. Zorrozua, "Impact assessment of clearance in corona testing for a high‐voltage substation connector set using fem," IET Generation, Transmission & Distribution, vol. 14, no. 18, pp. 3710-3718, 2020.

S. Y. Sheila, N. W. Rochamwati, F. Riyadi, R. F. As’ad, and A. T. Nugraha, "Desain and Build a Medium Voltage Cubicel Temperature and Humidity Optimization Tool to Minimize the Occurrence of Corona Disease with the PLC-Based Fuzzy Method," Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics, vol. 4, no. 4, pp. 192-198, 2022.

H. Chai, B. T. Phung, and S. Mitchell, "Application of UHF sensors in power system equipment for partial discharge detection: A review," Sensors, vol. 19, no. 5, p. 1029, 2019.

A. Alidemaj and I. Bula, "The negative effects of the corona effect on the propagation of radio and TV waves," IFAC-PapersOnLine, vol. 55, no. 39, pp. 342-345, 2022.

M. Borghei and M. Ghassemi, "Insulation materials and systems for more-and all-electric aircraft: A review identifying challenges and future research needs," IEEE Transactions on Transportation Electrification, vol. 7, no. 3, pp. 1930-1953, 2021.

L. Zhang, H. Chen, Q. Wang, N. Nayak, Y. Gong, and A. Bose, "A novel on-line substation instrument transformer health monitoring system using synchrophasor data," IEEE transactions on power delivery, vol. 34, no. 4, pp. 1451-1459, 2019.

D. Sacerdoţianu et al., "Contributions to monitoring the condition of substations," in 2019 8th International Conference on Modern Power Systems (MPS), 21-23 May 2019 2019, pp. 1-6, doi: 10.1109/MPS.2019.8759689.

N. Loganathan, J. Prasanth, R. S. Saravanan, V. Jayasuriya, and S. Karthikeyan, "Smart Substation Monitoring and Control," in 2021 7th International Conference on Advanced Computing and Communication Systems (ICACCS), 19-20 March 2021 2021, vol. 1, pp. 657-661, doi: 10.1109/ICACCS51430.2021.9442002.

S. U. Rehman, H. Mustafa, and A. R. Larik, "IoT Based Substation Monitoring & Control System Using Arduino with Data Logging," in 2021 4th International Conference on Computing & Information Sciences (ICCIS), 29-30 Nov. 2021 2021, pp. 1-6, doi: 10.1109/ICCIS54243.2021.9676384.




DOI: http://dx.doi.org/10.31963/intek.v10i2.4626

Refbacks

  • There are currently no refbacks.


Publisher by:

Politeknik Negeri Ujung Pandang
Kampus 1 Gedung Administrasi Lantai II
Jalan Perintis Kemerdekaan KM.10 Tamalanrea
Makassar 90245
E-mail: intek@poliupg.ac.id

INTEK Indexed by:

g61g61g61g61g61g61g61g61g61

Member of :

Creative Commons License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

View My Stats