Abstrak
Providing reliable and efficient electricity in the 20 kV distribution network is an important aspect in the operations of electricity supply companies such as PT. PLN (Persero). Sectionalizers, as devices or protection and control tools in distribution networks, have an important role in ensuring continuity of electricity supply and reducing disturbances that occur. Proper placement of the sectionalizer is an important factor in increasing operational efficiency and also reducing recovery time when a disruption occurs. This research aims to analyze the placement of sectionalizers in the 20 kV distribution network at Penyulang PT. PLN (Persero) with the aim of increasing the reliability of electricity supply. The research methodology involves field surveys, analysis of historical disturbance data, distribution network modeling and ETAP 19.0.1 simulations. These data are used to determine the optimal location of the sectionalizer and working parameters in accordance with network characteristics. The analysis results show that optimal sectionalizer placement can reduce the recovery time of electricity supply after a disturbance, increase the reliability of the distribution network and reduce economic losses due to power disturbances. Based on the calculation results after placing the sectionalizer in Sections B1 and B2, the values obtained were SAIDI = 0.03 and 0.05, SAIFI = 6.96 and 10.97 and CAIDI = 0.005 and 0.005.Referensi
Tryollinna, Azzahraninna. 2015. Studi Penempatan Sectionalizer Pada Jaringan Distribusi 20 KV di Penyulang Kelingi Untuk Meningkatkan Keandalan. Palembang: Universitas Sriwijaya.
Febriyanto, Nanang. 2018. Studi Penempatan Sectionalizer pada Jaringan Distribusi 20 KV di PT. PLN UPJ Klaten Kota Untuk Meningkatkan Keandalan. Jogjakarta: Universitas Teknologi Jogjakarta.
Politeknik Negeri Ujung Pandang. (2016). Pedoman Penulisan Proposal dan Skripsi Program Diploma Empat (D-4) Bidang Rekayasa dan Tata Niaga. Makassar: Politeknik Negeri Ujung Pandang.
Standar Perusahaan Umum Listrik Negara 59, (1985), Keandalan Pada Sistem Distribusi 20 kV dan 6 kV, Jakarta: Departemen Pertambangan dan Energi Perusahaan Listrik Negara.
Standar Perusahaan Umum Listrik Negara 68-2 (1986), Tingkat Jaminan Sistem Tenaga Listrik Bagian Dua: Sistem Distribusi, Jakarta: Departemen Pertambangan dan Energi Perusahaan Listrik Negara.
Suhadi, dkk. 2008. “Teknik Distribusi Tenaga Listrik”. Jakarta: Direktorat Jenderal Manajemen Pendidikan Dasar dan Menengah, Departemen Pendidikan Nasional.
Syufrijal, Monantun, Readysal. 2014. Jaringan distribusi Tenaga Listrik. Jakarta: Kementerian Pendidikan Dasar Menengah dan Kebudayaan RI
Zakki, Muhammad. 2015. Analisa Pengaruh Kegagalan Proteksi Terhadap Indeks Keandalan di Gardu Induk Talang Ratu PT. PLN (Persero) Menggunakan ETAP 12.6. Palembang: Politeknik Negeri Sriwijaya.
Husna, dkk. 2018. Menentukan Indeks SAIDI dan SAIFI Pada Saluran Udara Tegangan Menengah di PT. PLN Wilayah Nad Cabang Langsa. Sumatera Utara: Universitas Islam Sumatera Utara.
Derkanir, dkk. 2021. Evaluasi Keandalan Sistem Distribusi Menggunakan Indeks SAIFI dan SAIDI Pada PT. PLN (PERSERO) Area Bitung. Manado: Teknik Elektro Universitas Sam Ratulangi.
Erhaneli. 2015. Evaluasi Keandalan Sistem Distribusi Tenaga Listrik Berdasarkan Indeks Keandalan SAIDI dan SAIDFI Pada PT.PLN (Persero) Rayon Bagan Batu Tahun 2015. Padang: Jurnal Teknik Elektro ITP.