Analisa Kinerja Struktur Beton Bertulang Pasca Kebakaran

Authors

  • Abdullah Latip Jurusan Sipil PNUP

DOI:

https://doi.org/10.31963/intek.v3i2.58

Abstract

This Paper aims to analyze the performance level of Pasar Butung post-fire on December 15, 2010. The fire was centered on the 1st and 2nd floor. Data retrieval include visual observation, carbonation test, concrete hammer test, concrete core test and tensile test of steel reinforcement that was held on January, 2011. All data that was taken will use to analyze the structure. Observations indicate that the temperature of the fire around 400oC. Beams and columns on floors 1 and 2 had cracks and the quality of concrete fell 62% from 21.15 MPa to 14 MPa at the outer cross-section. While the floor plates 2 and 3 having a width of cracks and residual concrete quality is only 11.57 MPa. Pushover analysis (static lateral load) is a nonlinear static analysis that can provide detailed information about the collapse behavior of structures against earthquake loads, while the performance point is the magnitude of the maximum displacement of the structure during an earthquake plan. Results of 3D nonlinear static pushover analysis on the structure of Pasar Butung shows that performance point is achieved when the base reaction V reach 484.97 tons with displacement of 0.021 m (2.1 cm) at step 3. Results of analysis showed that the performance of the structure is still within the limits of Life Safety.

Author Biography

Abdullah Latip, Jurusan Sipil PNUP

Politeknik Negeri Ujung Pandang

References

Wei, M.L, Microstructure of Fire-Damaged Concrete, Aci Materials Journal Volume 3, No 3, Detroi, 1996.

Malhotra H. L., Design of Fire Resisting Structure, Surrey University Press, New York, 1982.

Irma, Kapastas Sisa Balok Pasca Bakar, Thesis Universitas Gadjah Mada, Yogyakarta, 2000.

Ingham J, Forensic Engineering of Fire-Damaged Structure, Proceedings of ICE, London, 2009.

ACI Committee 318, Building Code Requirements For Structural Concrete (ACI 318-2005) and Commentary (ACI 318R – 2005). American Concrete Institute, Detroi, 2005.

ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings, Applied Technology Council. Redwood City: California, 1996.

FEMA 356, Seismic Rehabilitation Prestandard, Am ericanSociety of Civil Engineers for the Federal Emergency Management Agency, Washington, D.C.

Published

2016-11-06