ANALISA DAN PENGECEKAN KERUSAKAN PADA PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO SETELAH SETAHUN BEROPERASI

Penulis

  • Jamal Jamal
  • Lewi Lewi
  • Anthonius Lorens Simons Haans

Abstrak

The operation of a Micro Hydro Power Plant (PLTMH) in order to have a long life requires regular maintenanceand checking of damage, periodic checks can be done in daily, weekly, monthly and annual time frames. This study aimsto determine the damage experienced by MHP after operating for one year. The benefits that can be obtained by regularlyanalyzing and checking damage from the MHP is to be able to extend the life of the MHP operation. The checkingmethod is done by measuring the turbine outflow flow, measuring the output generator rotation, observing turbine andgenerator rotation noise and measuring generator output voltage and current. The measurement results are then comparedwith the commissioner moment, namely when the MHP was first operated. If there is a deviation, an inspection of thefour main parts is carried out, namely on the dam (flow input), on the duct pipe, on the crossflow turbine and on thegenerator. The results obtained in this study are a decrease in flow discharge due to fertilization of the pipe line, there is adecrease and rotation of turbine noise due to bearing wear, the generator is unable to produce voltage and electric currentdue to damage to the generator.

Diterbitkan

2018-12-30

Terbitan

Bagian

MESIN, INDUSTRI, ENERGI, TEKNOLOGI PERTAHANAN, TEKNOLOGI RAMAH LINGKUNGAN, TEKNOLOGI TEPAT GUNA DAN PERTANIAN