Analysis of Energy Loss of Distribution Network of PT. PLN (Persero) ULP Banda Aceh

Authors

  • Fauzia Haz Universitas Jendral Achmad Yani
  • Andi Ahmad Fauzan Anshar Universitas Jendral Achmad Yani
  • Giri Angga Setia Universitas Jendral Achmad Yani
  • Naftalin Winanti Universitas Jendral Achmad Yani
  • Ahmad Daelami Universitas Jendral Achmad Yani

DOI:

https://doi.org/10.31963/elekterika.v22i1.5483

Keywords:

conductor uprating, distribution network, efficiency, energi losses, load balancing

Abstract

The aim of this research to identify areas requiring further attention to enhance electricity distribution efficiency. Data collection is conducted through observation and documentation methods to obtain secondary data such as Single Line Diagram, Distribution Transformer Load Current, Substation Voltage, Conductor Type, Conductor Length, and Conductor Cross-Sectional Area. Secondary data is processed and analyzed to obtain the conductor resistance value, conductor/line power losses, transformer power losses, total power losses, and total energi losses occurring in the distribution network using mathematical calculations, followed by simulation using the ETAP (Electrical Transient Analysis Program) application. After manually calculating power losses in the PT. PLN (Persero) ULP Banda distribution network at Penyulang Nusantara, which reached 7.84034 kW, the simulation results using the ETAP software show 7.8 kW, with a power loss percentage of 0.69% relative to the load. Following the simulation of improvement efforts using ETAP (conductor uprating and load balancing), power losses decrease to 4.4 kW (a reduction of 3.4 kW), with a percentage of 0.39%. The energi losses before improvement are 5,645.045 kWh (1.802%), and after improvement, it becomes 3,168 kWh (a reduction of 2,477 kWh) with a percentage of 1.59%. The improvement efforts result in savings of IDR 3,578,586.91.

References

[1] D. A. S and E. Ervianto, “Dengan Pendekatan Kurva Beban Pada Jaringan Distribusi Pt . Pln ( Persero ) Area Pekanbaru,” Jurnal Teknik Elektro, vol. 3, no. 2, p. 6, 2016.

[2] Z. Syamsudin and H. Suyanto, “Analisis Susut Energi Pada Tegangan Rendah Di Wilayah Pt. Pln (Persero) Area Bulungan,” Jurnal Sutet, vol. 5, no. 2, pp. 51–61, 2015.

[3] R. C. D. Sarikin, “ANALISIS SUSUT DAYA DAN ENERGI PADA JARINGAN DISTRIBUSI DI PT. PLN (Persero) RAYON PANAKKUKANG,” Jurnal Teknologi Elekterika, vol. 16 (1), no. 1, pp. 43–47, 2019.

[4] Arismunandar and Artono, Teknik Tegangan Tinggi. Jakarta: Pradnya Paramita, 2001.

[5] J. S. Setiadji, T. Machmudsyah, and Y. Isnanto, “Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral dan Losses pada Transformator Distribusi,” Jurnal Teknik Elektro, vol. 6, pp. 68–73, 2006.

[6] Y. Simanora, Panusur, and Tobing, “Analisis Ketidakseimbangan Beban Transformator Distribusi untuk Identifikasi Beban Lebih dan Estimasi Rugi-Rugi pada Jaringan Tegangan Rendah,” Singuda Ensikom, vol. 7(2), pp. 137–142, 2014.

[7] PT. PLN, Standar Kontruksi Sambungan Tenaga Listrik, no. Mi. Jakarta: PT.PLN, 2015.

[8] Sugiyono, Metode penelitian kuantitatif, kualitatif, R&D. Bandung: Alfabeta, 2019.

[9] M. Taufiq, “Perhitungan Rugi-Rugi Daya Saluran Distribusi Feeder Bangau Sakti Pada Gi Garuda Sakti Pt. Pln (Persero),” Jom FTEKNIK, vol. 8, no. 2016, pp. 1–7, 2021.

[10] A. M. Siregar, B. Badriana, H. M. Yusdartono, and A. Hasibuan, “Perbaikan Nilai Susut Teknis Jaringan Tegangan Menengah Pada Feeder K.H. 05 (Case Study PLN ULP Kruenggukuh),” Jurnal Energi Elektrik, vol. 12, no. 1, p. 24, 2023, doi: 10.29103/jee.v12i1.11708.